static
-void reset_sighandler(void)
+int reset_sighandler(void)
{
- int sig;
+ int sig, ret = 0;
DBG("Resetting run_as worker signal handlers to default");
for (sig = SIGHUP; sig <= SIGUNUSED; sig++) {
}
if (signal(sig, SIG_DFL) == SIG_ERR) {
PERROR("reset signal %d", sig);
+ ret = -1;
+ goto end;
}
}
+end:
+ return ret;
+}
+
+static
+void worker_sighandler(int sig)
+{
+ const char *signame;
+
+ /*
+ * The worker will its parent's signals since they are part of the same
+ * process group. However, in the case of SIGINT and SIGTERM, we want
+ * to give the worker a chance to teardown gracefully when its parent
+ * closes the command socket.
+ */
+ switch (sig) {
+ case SIGINT:
+ signame = "SIGINT";
+ break;
+ case SIGTERM:
+ signame = "SIGTERM";
+ break;
+ default:
+ signame = "Unknown";
+ }
+
+ DBG("run_as worker received signal %s", signame);
+}
+
+static
+int set_worker_sighandlers(void)
+{
+ int ret = 0;
+ sigset_t sigset;
+ struct sigaction sa;
+
+ if ((ret = sigemptyset(&sigset)) < 0) {
+ PERROR("sigemptyset");
+ goto end;
+ }
+
+ sa.sa_handler = worker_sighandler;
+ sa.sa_mask = sigset;
+ sa.sa_flags = 0;
+ if ((ret = sigaction(SIGINT, &sa, NULL)) < 0) {
+ PERROR("sigaction SIGINT");
+ goto end;
+ }
+
+ if ((ret = sigaction(SIGTERM, &sa, NULL)) < 0) {
+ PERROR("sigaction SIGTERM");
+ goto end;
+ }
+
+ DBG("run_as signal handler set for SIGTERM and SIGINT");
+end:
+ return ret;
}
LTTNG_HIDDEN
reset_sighandler();
+ set_worker_sighandlers();
+
/* The child has no use for this lock. */
pthread_mutex_unlock(&worker_lock);
/* Just close, no shutdown. */