Fix: Use default visibility for tracepoint provider symbol
authorMathieu Desnoyers <mathieu.desnoyers@efficios.com>
Sun, 27 Dec 2020 19:48:46 +0000 (14:48 -0500)
committerMathieu Desnoyers <mathieu.desnoyers@efficios.com>
Wed, 20 Jan 2021 16:59:32 +0000 (11:59 -0500)
commitd5ed6eddf99f8afcac6b2cb217b6678431b64968
tree45e1edf04d824bbe45f486eba5ec0180b012b412
parent4422005e3bc62f9103e964dceda7007bddb667ce
Fix: Use default visibility for tracepoint provider symbol

When building a probe provider `someprobe` with -fvisibility=hidden into
a shared library, the `__tracepoint_provider_someprobe` symbol is hidden,
which does not allow tracepoint instrumentation to link to it.

Fix this by using the "default" visibility attribute.

For a shared library built with -fvisibility=hidden, this changes the
output of nm for that symbol from:

000000000000417c b __tracepoint_provider_someprobe

(local BSS symbol)

to

000000000000417c B __tracepoint_provider_someprobe

(global (external) BSS symbol)

Fixes: #1296
Signed-off-by: Mathieu Desnoyers <mathieu.desnoyers@efficios.com>
Change-Id: I308374f6cac58cca86e8eb19c872286a3da21a75
include/lttng/ust-tracepoint-event.h