Fix: Use default visibility for tracepoint provider symbol
authorMathieu Desnoyers <mathieu.desnoyers@efficios.com>
Sun, 27 Dec 2020 19:48:46 +0000 (14:48 -0500)
committerMathieu Desnoyers <mathieu.desnoyers@efficios.com>
Wed, 20 Jan 2021 16:59:04 +0000 (11:59 -0500)
commit6c8cfec756dd209da46aa278133d4b2baaa5ea90
treea740377182e120657707d4153a7e458380d819af
parentf436dc743863f592579616940b015f8c1c33d999
Fix: Use default visibility for tracepoint provider symbol

When building a probe provider `someprobe` with -fvisibility=hidden into
a shared library, the `__tracepoint_provider_someprobe` symbol is hidden,
which does not allow tracepoint instrumentation to link to it.

Fix this by using the "default" visibility attribute.

For a shared library built with -fvisibility=hidden, this changes the
output of nm for that symbol from:

000000000000417c b __tracepoint_provider_someprobe

(local BSS symbol)

to

000000000000417c B __tracepoint_provider_someprobe

(global (external) BSS symbol)

Fixes: #1296
Signed-off-by: Mathieu Desnoyers <mathieu.desnoyers@efficios.com>
Change-Id: I308374f6cac58cca86e8eb19c872286a3da21a75
include/lttng/ust-tracepoint-event.h