Fix: relayd: connection abruptly closed on viewer stream creation failure
authorJérémie Galarneau <jeremie.galarneau@efficios.com>
Wed, 2 Mar 2022 17:59:17 +0000 (12:59 -0500)
committerJérémie Galarneau <jeremie.galarneau@efficios.com>
Tue, 8 Mar 2022 17:39:27 +0000 (12:39 -0500)
commit69e3782a3fb493f9600d2e104792ba87be58f625
treeb579533bb3aab49992b420f29f4d3b0424a81b9a
parentf75135f45f3cfead535cff72103217b029d0d5da
Fix: relayd: connection abruptly closed on viewer stream creation failure

Commit fe88e5175 explains (and fixes) an issue that could cause the
creation of viewer streams to fail. Currently, the error path causes the
relay daemon to abruptly close the connection to its live viewer peer.
This behaviour makes it impossible for the viewer to determine if an
error occurred or if the network connection simply failed.

Returning an `LTTNG_VIEWER_NEW_STREAMS_ERR` status code allows the
viewer to report a precise error. The viewer connection is closed since
the internal error is unlikely to be recoverable.

Signed-off-by: Jérémie Galarneau <jeremie.galarneau@efficios.com>
Change-Id: I557a8b66c1bd1c0bf361cfbabe962d8a6808f4f4