Fix relayd: initialize beacon to -1ULL
The relayd stream beacon_ts_end field is expected to have the value
-1ULL when unset (no beacon has been received since last index).
However, the initial state is wrong. It is left at the value 0, which
indicates that a live beacon has indeed been received (which is untrue),
which in turn causes a live beacon with ctf_stream_id of -1ULL to be
sent to babeltrace, which does not expect it, and fails.
This issue can be triggered with the following scenario:
1) create live session
2) setup UST per-uid buffers tracing
3) start tracing, without any active traced application
4) hook with babeltrace live client to view the trace
5) run a traced application
Step 5) will cause the babeltrace live client to receive a stream_id of
-1ULL, and error out.
Signed-off-by: Mathieu Desnoyers <mathieu.desnoyers@efficios.com>
Signed-off-by: Jérémie Galarneau <jeremie.galarneau@efficios.com>