* Is the information in this trace aligned ?
Yes (1) -> aligned on min(arch size, atomic data size).
No (0) -> data is packed.
-uint328 freq_scale
+uint32 freq_scale
event time is always calculated from :
trace_start_time + ((event_tsc - trace_start_tsc) * (freq / freq_scale))
uint64 start_freq
</struct>
</event>
+<event name=state_dump_facility_load>
+ <description>Facility used in the trace</description>
+ <struct>
+ <field name="name"><string/></field>
+ <field name="checksum"><uint size=4/></field>
+ <field name="id"><uint size=4/></field>
+ <field name="int_size"><uint size=4/></field>
+ <field name="long_size"><uint size=4/></field>
+ <field name="pointer_size"><uint size=4/></field>
+ <field name="size_t_size"><uint size=4/></field>
+ <field name="has_alignment"><uint size=4/></field>
+ </struct>
+</event>
+
<event name=time_heartbeat>
<description>System time values sent periodically to minimize cycle counter
drift with respect to real time clock and to detect cycle counter